Brand Name : HAIDA
Model Number : HD-F801-2
Certification : ISO 9001:2000; ISO 9001:2008
Place of Origin : Guangdong, China (Mainland)
MOQ : 1 Set
Price : Negotiable
Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram,In cash,escrow
Supply Ability : 30 Sets per Month Haida
Delivery Time : 5-8 work days
Packaging Details : ach set protected with resin fiber and PP film, then put into Strong wooden case with operation man
Loading Frequency : can be set
Test Stroke : 1000mm
Impact Height : 152mm
Warranty : 1 year
Backrest Load : 400N
Test Results : Output by built-in printer
Temperature Resolution : ±0.1℃
Counter Range : 0-99999 times
Handrail Loading Force : 250N
Flame Height : 35mm
Induction Mode : Precision load cell
Machine Specifications : 6.8 m × 2.6 m × 2.4 m
Dimensions : 3.5m x 2.4mx2.4m
Air Pressure : 4 ~ 7 bar
Position Resolution : min. 0.2 mm
HD-F801-2 Gas Chromatography
A whole set: Automatic thermal desorption apparatus+ Gas Chromatography+Hydrogen generator +Air generator
Technical Parameters of Gas Chromatography
| Furnace size | 28x 30 x18cm |
| Temperature range |
|
| Temperature setting | 1℃ |
| programmed heating rate | 0.1℃ |
| Maximum heating speed | 120℃/ min |
| Temperature stability | 0.01℃when the ambient temperature changes by 1℃ |
| Programmed temperature rise | 7-step programmed temperature rise |
| Loss compensation of operable column | dual channel |
| Power supply | 220V±10%,2500W (maximum) |
| Volume | 57x 55 x48 cm |
| Weight | around 50kg |
Technical Parameters of Detector:
| Hydrogen flame ionization detector (FID) | |
| Maximum operating temperature | 400℃ |
| Detection limit | ≤5 x 10-12g / S |
| Drift | ≤5 x 10-13a / 30min |
| Noise | 2 x 10-13a |
| Dynamic linear range | ≥107 |
| Thermal conductivity cell detector(TCD) | |
| Maximum operating temperature | 400℃ |
| Sensitivity | ≥10000 mv.ml/mg[n-C16] |
| Drift | ≤100uv / 30mi |
| Noise | ≤20ua |
| Dynamic linear range | ≥104 |
| Electronic capture detector (ECD) | |
| Maximum operating temperature | 350℃ |
| Detection limit | ≤6×10-15 g / ml (γ - 666) |
| Drift | ≤50uv / 30min |
| Noise | ≤20uv |
| Dynamic linear range | ≥104 |
Technical Parameters of Automatic thermal desorption apparatus
| Temperature control range of sample area | 5℃-400℃; Heat power:200W |
| Temperature control range of valve injection system | 5℃-180℃; Heat power:60W |
| Sample transfer line temperature control range | 5℃-200℃; Heat power:40W |
| Temperature Control Accuracy | < ±0.1℃ |
| Temperature control gradient | < ±0.1℃ |
| Desorption recovery | > 95% |
| Analog sampling flow | 100ml/min |
| Blowback cleaning flow | 0~200ml/min |
| Machine Size and Weight( L x W x H) | 400x170x300mm,Around 12kg |

|
|